Series
CL200 |
Series
CL250 |
[Not
heat treated] |
[Heat
treated] |

Material |
Hardness |
Finish |
Carbon
Steel SAE 1070-1080 |
CL200
HV 120 to 245 |
K Plain,
Oiled |
DIN
177222 WkNr 1.1248 |
CL250
HV 420 to 545 |
T Zinc
Plated |
CK75
and WkNr 1.1231 CK67 |
|
R Phosphate
Coated |
DIMENSIONAL
DATA
Unified |
Nominal
Bolt Size |
Installed
I.D. Min. |
Wall
Thickness |
OD |
Recommended
Hole Size
|
L* |
Rated
Proof Load (Lb.) |
CL200 |
CL250 |
#8 |
.193 |
.033 |
.265/.269 |
.259/.263 |
.312
to 2, +.000/-.006 |
810 |
1,770 |
#10 |
.221 |
.039 |
.305/.311 |
.299/.303 |
.312
to 2, +.000/-.006 |
1,100 |
2,400 |
1/4 |
.281 |
.044 |
.374/.381 |
.368/.372 |
.312
to 2, +.000/-.006 |
2,000 |
4,350 |
5/16 |
.344 |
.059 |
.468/.480 |
.462/.466 |
.312
to 2, +.000/-.008 |
3,200 |
6,950 |
3/8 |
.406 |
.073 |
.558/.574 |
.552/.556 |
.375
to 2, +.000/-.010 |
4,800 |
10,500 |
Metric |
Nominal
Bolt Size |
Installed
I.D. Min. |
Wall
Thickness |
OD |
Recommended
Hole Size
|
L* |
Rated
Proof Load (kN) |
CL200 |
CL250 |
M4 |
4.8 |
0.85 |
6.65/6.75 |
6.50/6.60 |
8
to 50, +0.0/-0.15 |
3.69 |
9.66 |
M5 |
5.8 |
1.00 |
7.95/8.10 |
7.80/7.90 |
8
to 50, +0.0/-0.15 |
5.96 |
15.6 |
M6 |
6.8 |
1.10 |
9.15/9.33 |
9.00/9.10 |
8
to 50, +0.0/-0.15 |
8.44 |
22.1 |
M8 |
8.8 |
1.50 |
11.90/12.20 |
11.75/11.85 |
8
to 50, +0.0/-0.20 |
15.4 |
40.3 |
M10 |
10.8 |
1.85 |
14.65/15.07 |
14.50/14.60 |
10
to 50, +0.0/-0.25 |
24.4 |
63.8 |
M12 |
12.8 |
2.25 |
17.45/18.00 |
17.30/17.40 |
14
to 50, +0.0/-0.25 |
35.4 |
92.7 |
| *Longer and shorter lengths on request. |
Compression
at Proof Load: |
| |
CL200
c = Lc x .0018 |
| |
CL250
c = Lc x .0047 |
Spirol® Standard
Split Seam Compression Limiters can
be installed with Spirol pin inserters,
pin driving chucks, or simply pressed in.
To
Order: BUSH, Nominal bolt diameter, Length, Material, Finish,
Series
Example: Bush 6 x 14 BK CL250
Series
CL100 |
Series
CL110 |
| Material |
Finish |
| E Brass |
K Plain |
DIMENSIONAL
DATA
Unified |
Nominal
Bolt Size |
Diameter
D |
Diameter
A |
Diameter
H |
T |
Recommended
Hole Size
|
L* |
Rated
Proof
Load (Lb.) |
#4 |
.136 |
.233 |
.276 |
.040 |
.224/.228 |
.125
to .375, +.000/-.006 |
360 |
#6 |
.170 |
.264 |
.308 |
.040 |
.255/.259 |
.188
to .500, +.000/-.006 |
560 |
#8 |
.194 |
.295 |
.339 |
.040 |
.286/.290 |
.188
to .563, +.000/-.006 |
810 |
#10 |
.221 |
.389 |
.443 |
.040 |
.380/.384 |
.250
to .563, +.000/-.006 |
1,100 |
1/4 |
.281 |
.452 |
.495 |
.063 |
.443/.447 |
.250
to .750, +.000/-.006 |
2,000 |
5/16 |
.346 |
.577 |
.620 |
.063 |
.568/.572 |
.250
to .750, +.000/-.006 |
3,200 |
3/8 |
.406 |
.702 |
.745 |
.063 |
.693/.697 |
.250
to .750, +.000/-.006 |
4,800 |
Metric |
Nominal
Bolt
Size |
Diameter
D |
Diameter
A |
Diameter
H |
T |
Recommended
Hole Size
|
L* |
Rated
Proof
Load (kN) |
M3 |
3.7 |
5.9 |
7.0 |
1.0 |
5.70/5.80 |
3.0
to 10.0, +0.0/-0.15 |
2.32 |
M4 |
4.8 |
7.5 |
8.6 |
1.0 |
7.30/7.40 |
5.0
to 14.0, +0.0/-0.15 |
3.78 |
M5 |
5.8 |
9.9 |
11.0 |
1.0 |
9.70/9.80 |
6.0
to 16.0, +0.0/-0.15 |
7.73 |
M6 |
6.8 |
11.50 |
12.6 |
1.6 |
11.25/11.35 |
6.0
to 20.0, +0.0/-0.15 |
8.44 |
M8 |
8.8 |
14.65 |
15.8 |
1.6 |
14.45/14.55 |
6.0
to 20.0, +0.0/-0.15 |
15.4 |
M10 |
10.8 |
17.85 |
18.9 |
1.6 |
17.60/17.70 |
6.0
to 20.0, +0.0/-0.15 |
24.4 |
| *Longer
and shorter lengths on request |
Compression
at Proof Load: |
| |
c
= Lc x .0017 |
Spirol® Standard
Split Seam Compression Limiters can
be installed with conventional ultrasonic welders,
Spirol Heat Insert Drivers, or simply pressed in.
To Order:
BUSH, Nominal Bolt Diameter, Length, Material, Finish, Series
Example: BUSH 6 x 14 EK CL100
|